Althon provide five versions of an Outfall Safety Grille, Version 1 is exactly as Figure C.6 of the ‘Sewers for Adoption Guidelines’ & Figure 10 of ‘Sewers for Scotland’. Hinged on one side, padlock facility on the opposing side and bars at 100mm spacing.

SFA Type 1 Grating up to 450mm Pipe

The Sewers for Adoption/Scotland compliant outfall safety grille should be used on outfalls of 350mm diameter or greater.  Manufactured from 70 x 70 x 10mm Steel Angle for the frame and 50 x 12mm Flat Bars at 100mm Spacing for the screen all fully galvanised to BS EN 1461 after manufacture. 

The grating is hinged on one side and provided with a padlock facility on the other.  The grating should be a minimum 270mm wider than the outside diameter of the pipe being used.  The grating & frame can be supplied with chemical anchor fixings to fit existing outfalls or supplied fitted to our Headwall range.